Evaluation of the pleth variability index, perfusion index, and other physiological parameters after COVID-19
Loading...
Date
2023
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Verduci Editore srl
Open Access Color
GOLD
Green Open Access
Yes
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
Objective: The aim of this study was to observe the changes in pleth variability index (PVI), perfusion index (PI) and other hemodynamic parameters in adult individuals who had had Coronavirus disease 2019 (COVID-19) and were currently living a normal life. A further aim was to draw attention to the fact that some hemodynamic changes after COVID-19 may cause long-term health problems.
Patients and methods: A total of 174 adult individuals who had had COVID-19 and were currently living a normal life and 56 healthy individuals with similar demographic characteristics who had not had COVID-19 were included in the study. The PI, PVI, oxygen saturation (SpO2), pulse rate (PR), total hemoglobin (Hgb), oxygen reserve index (ORI), and blood pressure values were measured by Masimo Radical 7. The data of individuals who had and did not have COVID-19 before were compared.
Results: The mean PVI (p = 0.008) and PI (p < 0.001) were significantly lower in people who had been exposed to COVID-19. Likewise, the mean of ORI, SpO2, and SpOC values was observed to be significantly lower in participants exposed to COVID-19 disease (p < 0.001, p < 0.001, and p = 0.006, respectively). The PVI had a positive correlation with body mass index (BMI) (r = 0.263, p < 0.001) and a negative correlation with SpO2 (r = -0.194, p = 0.003) and PR (r = 0.190, p = 0.004).
Conclusions: The PVI, PI, and other physiological parameters could potentially be useful for monitoring COVID-19 patients and evaluating their response to therapy. We believe that people who have been exposed to COVID-19 may be more susceptible to other diseases; therefore, they should be subjected to regular clinical checks.
Description
ORCID
Keywords
Coronavirus disease 2019, Pleth variability index, Perfusion index, Physiologic parameters, Adult, Perfusion Index, Oxygen, Hemodynamics, Humans, COVID-19, Blood Pressure, Oximetry, Coronavirus disease 2019, Pleth variability index, Perfusion index, Physiologic parameters
Fields of Science
03 medical and health sciences, 0302 clinical medicine
Citation
Gökdemİr G. Ş. (2023). Evaluation of the pleth variability index, perfusion index, and other physiological parameters after COVID-19. European review for medical and pharmacological sciences, 27(22), 11185–11191. https://doi.org/10.26355/eurrev_202311_34488
WoS Q
Scopus Q

OpenCitations Citation Count
N/A
Source
European Review for Medical and Pharmacological Sciences
Volume
27
Issue
22
Start Page
11185
End Page
11191
PlumX Metrics
Citations
Scopus : 1
PubMed : 1
Captures
Mendeley Readers : 2
SCOPUS™ Citations
1
checked on Mar 01, 2026
Web of Science™ Citations
1
checked on Mar 01, 2026
Page Views
9
checked on Mar 01, 2026
Downloads
293
checked on Mar 01, 2026
Google Scholar™

OpenAlex FWCI
0.262
Sustainable Development Goals
3
GOOD HEALTH AND WELL-BEING


