In situ atom trapping of Bi on W-coated slotted quartz tube flame atomic absorption spectrometry and interference studies

dc.contributor.author Kilinc, Ersin
dc.contributor.author Bakirdere, Sezgin
dc.contributor.author Aydin, Firat
dc.contributor.author Ataman, O. Yavuz
dc.date.accessioned 14.07.201910:50:10
dc.date.accessioned 2019-07-16T20:44:09Z
dc.date.available 14.07.201910:50:10
dc.date.available 2019-07-16T20:44:09Z
dc.date.issued 2013
dc.description.abstract Analytical performances of metal coated slotted quartz tube flame atomic absorption spectrometry (SQT-FAAS) and slotted quartz tube in situ atom trapping flame atomic absorption spectrometry (SQT-AT-FAAS) systems were evaluated for determination of Bi. Non-volatile elements such as Mo, Zr, W and Ta were tried as coating materials. It was observed that W-coated SQT gave the best sensitivity for the determination of Bi for SQT-FAAS and SQT-AT-FMS. The parameters for W-coated SQT-FAAS and W-coated SQT-AT-FAAS were optimized. Sensitivity of FAAS for Bi was improved as 4.0 fold by W-coated SQT-FAAS while 613 fold enhancement in sensitivity was achieved by W-coated SQT-AT-FAAS using 5.0 min trapping with respect to conventional FAAS. MIBK was selected as organic solvent for the re-atomization of Bi from the trapping surface. Limit of detection values for W-coated SQT-FAAS and W-coated SQT-AT-FAAS was obtained as 0.14 mu g mL(-1) and 0.51 ng mL(-1), respectively. Linear calibration plot was obtained in the range of 2.5-25.0 ng mL(-1) for W-coated SQT-AT-FAAS. Accuracy of the W-coated SQT-AT-FAAS system was checked by analyzing a standard reference material, NIST 1643e. (C) 2013 Elsevier B.V. All rights reserved. en_US
dc.description.sponsorship University of Dicle (DUBAP) [10-FF-31]; TUBITAK-BIDEP en_US
dc.description.sponsorship The present work was carried out under the financial support of University of Dicle (DUBAP; 10-FF-31) and TUBITAK-BIDEP. The authors thank Dr. Murat Kaya from METU for his help in Raman studies. en_US
dc.identifier.citation Kılınç, E., Bakırdere, S., Aydın, F., & Ataman, O. Y. (2013). In situ atom trapping of Bi on W-coated slotted quartz tube flame atomic absorption spectrometry and interference studies. Spectrochimica Acta Part B: Atomic Spectroscopy, 89, 14–19. https://doi.org/10.1016/j.sab.2013.08.008 en_US
dc.identifier.doi 10.1016/j.sab.2013.08.008
dc.identifier.issn 0584-8547
dc.identifier.scopus 2-s2.0-84884658566
dc.identifier.uri https://dx.doi.org/10.1016/j.sab.2013.08.008
dc.identifier.uri https://hdl.handle.net/20.500.12514/1412
dc.language.iso en en_US
dc.publisher PERGAMON-ELSEVIER SCIENCE LTD en_US
dc.relation.ispartof SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Metal coating en_US
dc.subject Bismuth en_US
dc.subject In situ atom trapping en_US
dc.subject Atomic absorption spectrometry en_US
dc.subject Slotted quartz tube en_US
dc.title In situ atom trapping of Bi on W-coated slotted quartz tube flame atomic absorption spectrometry and interference studies en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id Kilinc, Ersin -- 0000-0001-5223-9919
gdc.bip.impulseclass C5
gdc.bip.influenceclass C4
gdc.bip.popularityclass C5
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.collaboration.industrial false
gdc.description.department MAÜ, Meslek Yüksekokulları, Sağlık Hizmetleri Meslek Yüksekokulu, Tıbbi Hizmetler ve Teknikler Bölümü en_US
gdc.description.endpage 19 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q2
gdc.description.startpage 14 en_US
gdc.description.volume 89 en_US
gdc.description.wosquality Q1
gdc.identifier.openalex W2045077408
gdc.identifier.wos WOS:000327367000003
gdc.index.type WoS en_US
gdc.index.type Scopus en_US
gdc.oaire.diamondjournal false
gdc.oaire.downloads 0
gdc.oaire.impulse 3.0
gdc.oaire.influence 3.380817E-9
gdc.oaire.isgreen true
gdc.oaire.keywords Metal coating
gdc.oaire.keywords In situ atom trapping
gdc.oaire.keywords Atomic absorption spectrometry
gdc.oaire.keywords Bismuth
gdc.oaire.keywords Slotted quartz tube
gdc.oaire.keywords Atomic Absorption Spectrometry
gdc.oaire.keywords Slotted Quartz Tube
gdc.oaire.keywords Metal Coating
gdc.oaire.keywords In Situ Atom Trapping
gdc.oaire.popularity 1.5784896E-9
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 01 natural sciences
gdc.oaire.sciencefields 0104 chemical sciences
gdc.oaire.views 4
gdc.openalex.collaboration National
gdc.openalex.fwci 0.84710612
gdc.openalex.normalizedpercentile 0.74
gdc.opencitations.count 14
gdc.plumx.crossrefcites 14
gdc.plumx.mendeley 28
gdc.plumx.scopuscites 16
gdc.scopus.citedcount 16
gdc.virtual.author Kılınç, Ersin
gdc.wos.citedcount 14
relation.isAuthorOfPublication a7823274-c375-47c6-862b-43d44b1fd6b3
relation.isAuthorOfPublication.latestForDiscovery a7823274-c375-47c6-862b-43d44b1fd6b3
relation.isOrgUnitOfPublication 256d1c0a-4c75-476b-b468-80c6b6a899f2
relation.isOrgUnitOfPublication 98e86623-06a0-4127-be83-a120e4f62572
relation.isOrgUnitOfPublication 39ccb12e-5b2b-4b51-b989-14849cf90cae
relation.isOrgUnitOfPublication.latestForDiscovery 256d1c0a-4c75-476b-b468-80c6b6a899f2

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1-s2.0-S0584854713002310-main.pdf
Size:
350.57 KB
Format:
Adobe Portable Document Format
Description:
Full Text Article