MAÜ GCRIS Standart veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Load Frequency Control of Two Area Interconnected Power System Using Fuzzy Logic Control and Pid Controller

dc.authoridTUR, MEHMET RIDA/0000-0001-5688-4624
dc.authoridWadi, Mohammed/0000-0001-8928-3729
dc.authoridSHOBOLE, Abdulfetah Abdela/0000-0002-3180-6504
dc.authorscopusid57193870627
dc.authorscopusid57193868250
dc.authorscopusid56826062200
dc.authorscopusid23395943800
dc.authorwosidAy, Selim/AAZ-6146-2020
dc.authorwosidWadi, Mohammed/ABG-8088-2020
dc.authorwosidTur, Mehmet/W-3302-2018
dc.authorwosidSHOBOLE, Abdulfetah/AAU-2662-2020
dc.contributor.authorTur, Mehmet Rida
dc.contributor.authorWadi, Mohammed
dc.contributor.authorShobole, Abdulfetah
dc.contributor.authorAy, Selim
dc.date.accessioned2025-02-15T19:34:58Z
dc.date.available2025-02-15T19:34:58Z
dc.date.issued2018
dc.departmentArtuklu Universityen_US
dc.department-temp[Tur, Mehmet Rida] Mardin Artuklu Univ, Elect & Energy Dept, Mardin 47500, Turkey; [Wadi, Mohammed; Shobole, Abdulfetah] I Sabahettin Zaim Uni, Engn Dept, Istanbul, Turkey; [Ay, Selim] Yildiz Tech Univ, Elect Engn Dept, Istanbul, Turkeyen_US
dc.descriptionTUR, MEHMET RIDA/0000-0001-5688-4624; Wadi, Mohammed/0000-0001-8928-3729; SHOBOLE, Abdulfetah Abdela/0000-0002-3180-6504en_US
dc.description.abstractDemand for electricity is constantly increasing day by day. The biggest challenge is to provide uninterrupted and high-quality electricity to customers in variable conditions. To accomplish this, the two parameters must always be checked for each condition; these parameters are load distribution and network frequency. In this study, fuzzy logic and Proportional Integral Derivative controller method is applied in power system connected with two different fields to remove the fluctuations of electric energy. For this, MATLAB offers simulation applications and models in Simulink. Both different control directions are compared according to the results obtained. To emphasize the effectiveness of the proposed fuzzy control system, two field-connected power systems were simulated in four scenarios in a wide range of operating conditions. In addition to all these, the performance of the proposed method is compared with a Proportional Integral Derivative tester with simulation studies and the results show the effectiveness and superiority of the proposed approach.en_US
dc.description.provenanceSubmitted by GCRIS Admin (gcris@artuklu.edu.tr) on 2025-02-15T19:34:57Z No. of bitstreams: 0en
dc.description.provenanceMade available in DSpace on 2025-02-15T19:34:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2018en
dc.description.woscitationindexConference Proceedings Citation Index - Science
dc.identifier.citationcount7
dc.identifier.endpage1258en_US
dc.identifier.isbn9781538659823
dc.identifier.issn2377-6897
dc.identifier.scopus2-s2.0-85060566879
dc.identifier.scopusqualityN/A
dc.identifier.startpage1253en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12514/6002
dc.identifier.wosWOS:000457681100205
dc.identifier.wosqualityN/A
dc.language.isoenen_US
dc.publisherIeeeen_US
dc.relation.ispartof7th International Conference on Renewable Energy Research and Applications (ICRERA) -- OCT 14-17, 2018 -- Paris, FRANCEen_US
dc.relation.ispartofseriesInternational Conference on Renewable Energy Research and Applications
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFuzzy Systemsen_US
dc.subjectFrequency Controlen_US
dc.subjectMatlaben_US
dc.subjectPower System Controlen_US
dc.subjectProportional Controlen_US
dc.titleLoad Frequency Control of Two Area Interconnected Power System Using Fuzzy Logic Control and Pid Controlleren_US
dc.typeConference Objecten_US
dspace.entity.typePublication

Files