Elektrik ve Enerji Bölümü Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/20.500.12514/174
Browse
Browsing Elektrik ve Enerji Bölümü Koleksiyonu by Department "Artuklu University"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Conference Object Citation - WoS: 0Citation - Scopus: 0Abnormal Heart Sound Detection Using Ensemble Classifiers(Institute of Electrical and Electronics Engineers Inc., 2019) Zan, H.; Yildiz, A.; Zan, Hasan; Department of Computer Engineering / Bilgisayar Mühendisliği BölümüPhonocardiogram is used for ambulatory diagnostic to assess health status of heart and detect cardiovascular disease. The goal of this study is to develop automatic classification method of PCG recordings collected from different databases and recorded in a different way. For this purpose, after various time and frequency domain features are extracted from PCG recordings obtained from two databases, recordings are subjected to pre-classification in order determine which database they are obtained from. Before final classification, various time, frequency and time-frequency domain features of classified recordings are extracted. These features are fed into four different classification ensembles trained with training dataset. With final decision rule, proposed algorithm achieved an accuracy of 98.9%, a sensitivity of 93.75% and a specify of 99.5%. © 2018 IEEE.Article Citation - WoS: 22Citation - Scopus: 23Developed Analytical Expression for Current Harmonic Distortion of the Pv System's Inverter in Relation To the Solar Irradiance and Temperature(Springer, 2021) Adak, Suleyman; Adak, Süleyman; Cangi, Hasan; Eid, Bilal; Yilmaz, Ahmet Serdar; Department of Electricity and Energy / Elektrik ve Enerji BölümüThis paper deals with modeling and simulation of the total harmonic distortion of the current (THDI) dispatched from the inverter and connected to nonlinear load. The change of THD(I)was examined in relation to the ambient temperature (T) and solar irradiance (G). The developed model is being used to extract parameters for a given THD(I)as a function of temperature and solar radiation. This study outlines the working principle of photovoltaic (PV) panel as well as PV array. Off-grid PV system is modeled by using Matlab/Simulink program, and detailed analytical study has been carried out in this work. The design, modeling and simulation of this study are performed from 50 up to 988 W/m(2)for solar irradiance. Harmonic components have negative effects on the steady-voltage stability of the PV system. Therefore, analytical expression is needed for steady-state stability analysis in order to reduce negative effects. Hence, two analytical expressions of THD(I)were obtained by two new different methods which are statistical package for the social sciences program and genetic expression programming. Eventually, two different methods have been verified by the Matlab/Simulink program in order to find out THD(I)and demonstrated the effectiveness of the proposed strategy. As a result of this study, it is observed that input current THDI of nonlinear load is too high at low irradiance. It is suggested that active harmonic filters should be used at low irradiance in order to produce better quality energy and avoid damages in the PV system.Article Citation - WoS: 5Citation - Scopus: 6The quality problems at low irradiance in the grid-connected photovoltaic systems(Springer Science and Business Media Deutschland GmbH, 2024) Adak, Süleyman; Cangi, H.; Department of Electricity and Energy / Elektrik ve Enerji BölümüSolar photovoltaic (PV) energy is one of the most prominent topics that have attracted the attention of researchers in recent years. The use of solar energy is increasing rapidly in the world. Although using PV energy has various advantages, it has some disadvantages. Among these disadvantages, power factor (PF) and total harmonic distortion (THD) issues are discussed in this article. When solar PV systems are integrated into the grid, various power quality problems arise. In addition, due to low power quality and high harmonics, power system components overheat and start operating in undesirable regions; causes great damage. The magnitude of PF and THD is dependent on solar irradiation values. In order to determine how the power quality in the grid-connected solar system is affected by changes in solar irradiation (G), results for various irradiation situations are presented and analyzed. In addition, at low irradiance values, the amplitude of harmonic components and reactive power increases, whereas the power factor of the PV system decreases. Low power factor and high amplitude of harmonics cause the efficiency of the solar system to decrease. In this study, PF and THDI values were measured on a particular cloudy day for analysis. An analysis of the solar PV system was conducted using Matlab/simulation program to model the grid-connected PV system. Thus, the analytical expression of the PF and THDI, which are dependent on irradiation, was found with a new method by using the Statistical Package for the Social Sciences (SPSS) program and the curve fitting method. Obtaining the analytical expressions for both solar irradiation (G) and power factor (PF) used the SPSS program and also solar irradiation (G) and total harmonic distortion (THDI) used the MATLAB curve fitting method which contributed to the science comparing to the existing literature. It can be prevented the low power quality by using such these expressions at low solar irradiation cases. © The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2024.