The effect of coronary slow flow on ventricular repolarization parameters
dc.authorid | 0000-0001-6985-6112 | |
dc.authorwosid | HCH-3800-2022 | |
dc.contributor.author | Günlü, Serhat | |
dc.contributor.author | Karahan, Mehmet Zülkif | |
dc.contributor.author | Aktan, Adem | |
dc.contributor.author | Kılıç, Raif | |
dc.contributor.author | Kılıç, Raif | |
dc.contributor.other | Department of Internal Medical Sciences / Dahili Tıp Bilimleri Bölümü | |
dc.date.accessioned | 2023-12-11T12:37:17Z | |
dc.date.available | 2023-12-11T12:37:17Z | |
dc.date.issued | 2023 | |
dc.department | MAÜ, Fakülteler, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Kardiyoloji Ana Bilim Dalı | en_US |
dc.description.abstract | Introduction: Ischemia due to microvascular dysfunction may be responsible for the heterogeneity of ventricular repolarization in coronary slow flow. To our knowledge, there is no study in which QT interval, Tp-Te interval, index of cardiac-electrophysiological balance (iCEB), and frontal QRS-T angle were evaluated together in patients with CSF. In this study, we examined for the first time the relationship between all these myocardial repolarization parameters and CSF. Materials and methods: The study group included 178 patients (99 female, mean age: 50.6 ± 8.6 years) with isolated CSF without stenotic lesions and with angiographically proven normal coronary arteries. The control group included 120 patients (71 female, mean age: 49.3 ± 9.4 years) with normal coronary angiography. QRS duration, QT interval, QTc interval, Tp-Te interval, Tp-Te/QT, Tp- Te/QTc, iCEB score, and frontal QRS-T angle were calculated from 12‑lead ECGs. Results: There was no significant difference in demographic parameters between the two groups. Compared with the control group, patients with CSF had significantly longer QTmax duration, QT dispersion, Tp-Te interval, and higher iCEB score, wider frontal QRS-T angle. Conclusion: In our study, we found that many of the ventricular repolarization parameters were adversely affected in patients with CSF. Impaired parameters may be associated with the risk of malignant ventricular arrhythmias. | en_US |
dc.identifier.doi | 10.1016/j.jelectrocard.2023.01.008 | |
dc.identifier.endpage | 43 | en_US |
dc.identifier.issn | 0022-0736 | |
dc.identifier.issue | 3 | en_US |
dc.identifier.startpage | 39 | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.12514/4543 | |
dc.identifier.volume | 78 | en_US |
dc.identifier.wosquality | Q4 | |
dc.institutionauthor | Günlü, Serhat | |
dc.language.iso | en | en_US |
dc.publisher | ELSEVIER | en_US |
dc.relation.ispartof | Journal of Electrocardiology | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.title | The effect of coronary slow flow on ventricular repolarization parameters | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 89c76ff7-b4d6-4481-9e5f-dce4dc922619 | |
relation.isAuthorOfPublication | 1cf334d3-4ee1-4f6d-8af1-cb0cba29287d | |
relation.isAuthorOfPublication | 967396ba-c270-4fb3-bf80-d92822330441 | |
relation.isAuthorOfPublication | ab85104a-1479-4823-9116-6b63c0ba0a81 | |
relation.isAuthorOfPublication.latestForDiscovery | 89c76ff7-b4d6-4481-9e5f-dce4dc922619 | |
relation.isOrgUnitOfPublication | 8e5859b2-b0cf-4e18-9816-a07bcf1aa7ca | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8e5859b2-b0cf-4e18-9816-a07bcf1aa7ca |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- ec3aa18e4fb69002919a1526b2279b0807bf56b79241a34b1348119518890e99.pdf
- Size:
- 721.46 KB
- Format:
- Adobe Portable Document Format
- Description:
- Tam Metin-text
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.44 KB
- Format:
- Item-specific license agreed upon to submission
- Description: