dc.description.abstract Introduction: Ischemia due to microvascular dysfunction may be responsible for the heterogeneity of ventricular repolarization in coronary slow flow. To our knowledge, there is no study in which QT interval, Tp-Te interval, index of cardiac-electrophysiological balance (iCEB), and frontal QRS-T angle were evaluated together in patients with CSF. In this study, we examined for the first time the relationship between all these myocardial repolarization parameters and CSF. Materials and methods: The study group included 178 patients (99 female, mean age: 50.6 ± 8.6 years) with isolated CSF without stenotic lesions and with angiographically proven normal coronary arteries. The control group included 120 patients (71 female, mean age: 49.3 ± 9.4 years) with normal coronary angiography. QRS duration, QT interval, QTc interval, Tp-Te interval, Tp-Te/QT, Tp- Te/QTc, iCEB score, and frontal QRS-T angle were calculated from 12‑lead ECGs. Results: There was no significant difference in demographic parameters between the two groups. Compared with the control group, patients with CSF had significantly longer QTmax duration, QT dispersion, Tp-Te interval, and higher iCEB score, wider frontal QRS-T angle. Conclusion: In our study, we found that many of the ventricular repolarization parameters were adversely affected in patients with CSF. Impaired parameters may be associated with the risk of malignant ventricular arrhythmias. en_US
dc.identifier.doi 10.1016/j.jelectrocard.2023.01.008
dc.identifier.issn 0022-0736
dc.identifier.uri https://hdl.handle.net/20.500.12514/4543
dc.language.iso en en_US
dc.publisher ELSEVIER en_US
dc.relation.ispartof Journal of Electrocardiology en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.title The effect of coronary slow flow on ventricular repolarization parameters en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id 0000-0001-6985-6112
gdc.author.institutional Günlü, Serhat
gdc.author.wosid HCH-3800-2022
gdc.description.department MAÜ, Fakülteler, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Kardiyoloji Ana Bilim Dalı en_US
gdc.description.endpage 43 en_US
gdc.description.issue 3 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.startpage 39 en_US
gdc.description.volume 78 en_US
gdc.description.wosquality Q4
relation.isAuthorOfPublication 89c76ff7-b4d6-4481-9e5f-dce4dc922619
relation.isAuthorOfPublication 1cf334d3-4ee1-4f6d-8af1-cb0cba29287d
relation.isAuthorOfPublication 967396ba-c270-4fb3-bf80-d92822330441
relation.isAuthorOfPublication ab85104a-1479-4823-9116-6b63c0ba0a81
relation.isAuthorOfPublication.latestForDiscovery 89c76ff7-b4d6-4481-9e5f-dce4dc922619
relation.isOrgUnitOfPublication 8e5859b2-b0cf-4e18-9816-a07bcf1aa7ca
relation.isOrgUnitOfPublication 3f27f943-1869-4252-af6a-9ec8b114c727
relation.isOrgUnitOfPublication 39ccb12e-5b2b-4b51-b989-14849cf90cae
relation.isOrgUnitOfPublication.latestForDiscovery 8e5859b2-b0cf-4e18-9816-a07bcf1aa7ca

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ec3aa18e4fb69002919a1526b2279b0807bf56b79241a34b1348119518890e99.pdf
Size:
721.46 KB
Format:
Adobe Portable Document Format
Description:
Tam Metin-text

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: