Elektrik ve Enerji Bölümü
Permanent URI for this communityhttps://hdl.handle.net/20.500.12514/112
Browse
Browsing Elektrik ve Enerji Bölümü by Author "Shobole, Abdulfetah"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Article Citation - Scopus: 20Effects of distributed generations' integration to the distribution networks case study of solar power plant(İlhami Çolak, 2017) Shobole, Abdulfetah; Baysal, Mustafa; Wadi, Mohammed; Tur, Mehmet Rida; 17.02. Department of Electricity and Energy / Elektrik ve Enerji Bölümü; 17. Vocational Higher School / Meslek Yüksekokulu; 01. Mardin Artuklu University / Mardin Artuklu ÜniversitesiAll over the world, the Distributed Generations (DGs) integration to power system has increased in the recent years due to economic, environmental and technical advantages. Turkey which has the huge solar potential has focused on integrating both licensed and unlicensed solar power plants by providing 10 years of purchasing guarantee as an incentive for the electricity producers from solar energy. However, the integration of DGs has several negative effects on the distribution networks (DNs). This work is concerned with investigating the possible challenges that may arise due to integration of PV based DGs on the existing distribution networks. Short circuit current level with respect to variation in MW integration is studied for the case the utility network is weak and strong. When the utility network is strong, the integration effect of inverter based DGs like solar power plants were observed insignificant. However, for the weak utility networks, the integration of inverter based DGs has been observed to have significant influence. Finally, directly integrated DGs (without inverter) are considered to reveal its difference with the non-inverter based DGs. As the case study, the distribution network integration of a solar power project, which is found in the Antalya region of Turkey, is investigated. This is 12 MW solar power plant designed to be connected to the local distribution network in Antalya. It is concluded that the effects of directly integrated DGs are observed more prominent compared to the inverter based DGs. DigSILENT Power Factory simulation tool is used for the study.Article Citation - WoS: 4Güç sistemlerinde ünite tahsisi için döner rezerv gereksinimi optimal değerinin kayıp parametrelerin dikkate alınarak hesaplanması(Gazi Üniversitesi, 2019) Tür, Mehmet Rıda; Ay, Selim; Shobole, Abdulfetah; Wadi, Mohammed; 17.02. Department of Electricity and Energy / Elektrik ve Enerji Bölümü; 17. Vocational Higher School / Meslek Yüksekokulu; 01. Mardin Artuklu University / Mardin Artuklu ÜniversitesiDöner Rezerv, üretim kesintileri ve ani yük değişimleri gibi öngörülemeyen olaylara yanıt olarak sistem operatörleri tarafından kullanılan en önemli kaynaklardan biridir. Kullanılacak rezervlerin miktarını yüksek tutarak doğabilecek beklenmedik durumların sebep olduğu üretim kesintilerine karşı güç sistemini korumak mümkün olur, bu işlem karşısında yük atma işleminin uygulanma olasılığı azalır, fakat bu durumda rezerv sağlama oldukça yüksek bir maliyet ile sonuçlanır. Maliyeti düşürmek amacıyla rezerv miktarını düşük tutma durumunda ise olası kesinti ve arıza durumlarında sağlanamayan bir enerji söz konusu olur ve tüketiciler enerjisiz kalabilir. Bu iki durumu dengeleyici şekilde bir ekonomik incelemeye gerek duyulmaktadır. Geleneksel Ünite Tahsis formülasyonlarında, Döner Rezerv gereksinimini ayarlamak için en büyük çevrimiçi jeneratörün kapasitesi olarak belirleme yapan deterministik kriterler ile sabit bir rezerv miktarı benimsenir. Bu çalışmada, güç sisteminde tahsis edilmesi gerek Döner Rezerv gereksinimi, sağlanamayan enerji miktarı ve kayıp yük değeri gibi sosyo ekonomik parametreler dikkate alınarak elde edilir. Bu değer için fayda maliyet temeline dayalı bir yöntem ile hesaplama yapılmaktadır.