Protection Coordination Practice in Electrical Substation Part-1 Overcurrent and Earth Fault Protection - Case Study of Siddik Kardesler Substation (SKS), Istanbul, Turkey

dc.contributor.author Tür, Mehmet Rıda
dc.contributor.author Baysal, Mustafa
dc.contributor.author Wadi, Mohammed
dc.contributor.author Tur, Mehmet Rida
dc.contributor.other Department of Electricity and Energy / Elektrik ve Enerji Bölümü
dc.date.accessioned 14.07.201910:50:10
dc.date.accessioned 2019-07-16T20:43:58Z
dc.date.available 14.07.201910:50:10
dc.date.available 2019-07-16T20:43:58Z
dc.date.issued 2017
dc.department [Belirlenecek] en_US
dc.department-temp [Shobole, Abdulfetah -- Wadi, Mohammed] Istanbul Sabahettin Zaim Univ, Elect & Elect Engn Dept, Halkali Mahallesi,Halkali Caddesi, TR-34303 Istanbul, Turkey -- [Baysal, Mustafa] Yildiz Tech Univ, Dept Elect Engn, Davutpasa St, TR-34220 Istanbul, Turkey -- [Tur, Mehmet Rida] Mardin Artuklu Univ, Elect Engn Dept, Diyarbakir St Yenisehir Campus, Mardin, Turkey en_US
dc.description.abstract Protection coordination is the heart of all power systems. To ensure a quality and reliable operation of the power systems, an electrical fault must be cleared within a short time. This can be achieved by proper coordination between the protection relays. In Siddik Kardesler Substation the MV voltage feeders' protection is provided by overcurrent relays. This paper is principally concerned with practical protection coordination of the electrical substation by using Siddik Kardesler Substation substation as a case study. In the Part-2, distance and differential protection will be discussed. Finally, after test and commissioning, the substation is successfully energized without a problem. en_US
dc.identifier.endpage 198 en_US
dc.identifier.issn 2147-1762
dc.identifier.issue 4 en_US
dc.identifier.startpage 180 en_US
dc.identifier.uri https://hdl.handle.net/20.500.12514/1312
dc.identifier.volume 30 en_US
dc.identifier.wos WOS:000418818000015
dc.indekslendigikaynak Web of Science en_US
dc.language.iso en en_US
dc.publisher GAZI UNIV en_US
dc.relation.ispartof GAZI UNIVERSITY JOURNAL OF SCIENCE en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Earth Fault Protection en_US
dc.subject Over Current Protection en_US
dc.subject Protection Coordination en_US
dc.subject Electrical Substation en_US
dc.title Protection Coordination Practice in Electrical Substation Part-1 Overcurrent and Earth Fault Protection - Case Study of Siddik Kardesler Substation (SKS), Istanbul, Turkey en_US
dc.type Article en_US
dc.wos.citedbyCount 1
dspace.entity.type Publication
relation.isAuthorOfPublication cd338cd1-1a9a-4f75-8a65-f7f68957d545
relation.isAuthorOfPublication.latestForDiscovery cd338cd1-1a9a-4f75-8a65-f7f68957d545
relation.isOrgUnitOfPublication 18bfdd41-2c86-4bb6-acf5-15548d923960
relation.isOrgUnitOfPublication.latestForDiscovery 18bfdd41-2c86-4bb6-acf5-15548d923960

Files