MAÜ GCRIS Standart veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Analysis of legionella and Some Chemicals in Water Samples in Mardin Province

dc.authorid DUNDAR, ABDURRAHMAN/0000-0002-7930-1054
dc.authorwosid DUNDAR, ABDURRAHMAN/AAN-2569-2020
dc.contributor.author Dündar, Abdurrahman
dc.contributor.author Yildirim, Idris
dc.contributor.author Dundar, Nagihan Demir
dc.contributor.other Department of Medical Services and Techniques / Tıbbi Hizmetler ve Teknikleri Bölümü
dc.date.accessioned 2025-02-15T19:33:42Z
dc.date.available 2025-02-15T19:33:42Z
dc.date.issued 2022
dc.department Artuklu University en_US
dc.department-temp [Dundar, Abdurrahman] Mardin Artuklu Univ, Saglik Hizmetleri Meslek Yuksekokulu, Mardin, Turkey; [Yildirim, Idris] Diyarbakir Saglik Mudurlugu, Halk Sagligi Lab, Diyarbakir, Turkey; [Dundar, Nagihan Demir] Adnan Menderes Anadolu Lisesi, Diyarbakir Milli Egitim Mudurlugu, Diyarbakir, Turkey en_US
dc.description DUNDAR, ABDURRAHMAN/0000-0002-7930-1054 en_US
dc.description.abstract In this study microbiological and chemical analyzes were carried out on water and swab samples taken from two water wells, a water tank and taps of buildings belonging to a public institution in Mardin Province. In these specimens the presence of Legionella and its serogroups as well as the parameters such as chlorine, nitrate, nitrite concentration, pH level and electrical conductivity were analyzed. While Legionella growth was not observed in 25 water samples, L. pneumophila serogroup 1 was detected in 4 of 25 swab culture samples taken from the same places. The pH values of water samples ranged from 7.53 to 8.02 the lowest pH value was observed in well no 1 as 7.53 while the highest was observed in well no 2 as 8.02. The lowest electrical conductivity value was measured at well 2 as 376.44 mu S cm(-1) and the highest was measured as 446.57 mu S/cm from well 1. As a result of the analyzes made in our research nitrite was not detected in any of the water samples. Whilst the nitrate amount was found to be the lowest with 4.30 ppm in the well, the highest with 10.85 ppm in the well 2. The chlorine values in the well 1 and 2 from which water samples were taken and the main tank were measured as 2.21, 2.05 and 2.43 ppm respectively. These values were found to be in the range of 1.68-1.73 ppm in the samples taken from the building taps. en_US
dc.description.woscitationindex Emerging Sources Citation Index
dc.identifier.citationcount 0
dc.identifier.doi 10.18016/ksutarimdoga.vi.1066856
dc.identifier.endpage 390 en_US
dc.identifier.issn 2619-9149
dc.identifier.scopusquality N/A
dc.identifier.startpage 382 en_US
dc.identifier.trdizinid 1169510
dc.identifier.uri https://doi.org/10.18016/ksutarimdoga.vi.1066856
dc.identifier.uri https://hdl.handle.net/20.500.12514/5922
dc.identifier.volume 25 en_US
dc.identifier.wos WOS:000956730400011
dc.language.iso tr en_US
dc.publisher Kahramanmaras Sutcu Imam Univ Rektorlugu en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Mardin en_US
dc.subject Legionella en_US
dc.subject Water Analysis en_US
dc.subject Microbiological en_US
dc.subject Chemical en_US
dc.title Analysis of legionella and Some Chemicals in Water Samples in Mardin Province en_US
dc.type Article en_US
dc.wos.citedbyCount 0
dspace.entity.type Publication
relation.isAuthorOfPublication 4dbc1aa6-5cf3-400f-a0dc-c7dba6f3cb32
relation.isAuthorOfPublication.latestForDiscovery 4dbc1aa6-5cf3-400f-a0dc-c7dba6f3cb32
relation.isOrgUnitOfPublication 256d1c0a-4c75-476b-b468-80c6b6a899f2
relation.isOrgUnitOfPublication.latestForDiscovery 256d1c0a-4c75-476b-b468-80c6b6a899f2

Files