MAÜ GCRIS Standart veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Trace Metal Determination in the Medicinal Plant Hyoscyamus (Solanaceae) by Inductively Coupled Plasma Optical Emission Spectrometry

dc.authorscopusid57819807000
dc.authorscopusid56452832800
dc.authorscopusid23037730000
dc.contributor.authorKeskin, C.
dc.contributor.authorKisin, E.
dc.contributor.authorYavuz, M.
dc.date.accessioned14.07.201910:50:10
dc.date.accessioned2019-07-16T20:44:07Z
dc.date.available14.07.201910:50:10
dc.date.available2019-07-16T20:44:07Z
dc.date.issued2014
dc.departmentArtuklu Universityen_US
dc.department-tempKeskin C., Department of Nutrition and Dietetics, School of Health, Mardin Artuklu University, Mardin, 47100, Turkey; Kisin E., Department of Chemistry, Faculty of Science, Dicle University, Diyarbakir, 21280, Turkey; Yavuz M., Department of Chemistry, Faculty of Science, Dicle University, Diyarbakir, 21280, Turkeyen_US
dc.description.abstractThe concentrations of Cd, Ni, Cu, Pb, Cr, Fe, B, and A1 were determined in four different medicinal plants of the Hyoscyamus species: Hyoscyamus reticulums L, Hyoscyamus leptocalyx STAPF, Hyoscyamus aureus L, and Hyoscyamus albus L by ICP-OES. By considering the sensitivity of ICP-OES with respect to the trace level determination of Cd, Ni, Cu, Pb, Cr, Fe, B, and Al in the studied plant samples and the limitations of sample amount possible in a microwave digestion procedure, the ashing method was applied before analysis and proved the quantitative measurements of the elements.The accuracy of the method was verified by comparison to the certified reference sample NCSZC 73014 Tea Leaves. The RSD values were between 0.14-10.4%, while the error values were in the 90-107% range. The results show that with the proposed method higher concentrations of Ni, Cr, Pb, Fe, and B were determined in H. aureus. Interestingly, the concentration of Cu in H. reticulatus was approximately 48.5 times higher than the mean Cu values of the other three Hyoscyamus species, while the Pb concentration levels in H. aureus were 17.8 times higher than in the H. reticulatus L, H. leptocalyx STAPF, and H. albus L species.en_US
dc.description.provenanceSubmitted by Ideal DSpace (dspace@artuklu.edu.tr) on 14.07.201910:50:10en
dc.description.provenanceMade available in DSpace on 2019-07-16T20:44:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2014en
dc.identifier.doi10.46770/AS.2014.05.002
dc.identifier.endpage199en_US
dc.identifier.issn0195-5373
dc.identifier.issue5en_US
dc.identifier.scopus2-s2.0-84919337029
dc.identifier.scopusqualityQ2
dc.identifier.startpage193en_US
dc.identifier.volume35en_US
dc.identifier.wosWOS:000344511300002
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherPerkin - Elmer Corp.en_US
dc.relation.ispartofAtomic Spectroscopyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleTrace Metal Determination in the Medicinal Plant Hyoscyamus (Solanaceae) by Inductively Coupled Plasma Optical Emission Spectrometryen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
keskın.pdf
Size:
154.34 KB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text