MAÜ GCRIS Standart veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Trace Metal Determination in the Medicinal Plant Hyoscyamus (Solanaceae) by Inductively Coupled Plasma Optical Emission Spectrometry

dc.authorscopusid 57819807000
dc.authorscopusid 56452832800
dc.authorscopusid 23037730000
dc.contributor.author Keskin, Cumali
dc.contributor.author Kisin, E.
dc.contributor.author Yavuz, M.
dc.contributor.other Department of Medical Services and Techniques / Tıbbi Hizmetler ve Teknikleri Bölümü
dc.date.accessioned 14.07.201910:50:10
dc.date.accessioned 2019-07-16T20:44:07Z
dc.date.available 14.07.201910:50:10
dc.date.available 2019-07-16T20:44:07Z
dc.date.issued 2014
dc.department Artuklu University en_US
dc.department-temp Keskin C., Department of Nutrition and Dietetics, School of Health, Mardin Artuklu University, Mardin, 47100, Turkey; Kisin E., Department of Chemistry, Faculty of Science, Dicle University, Diyarbakir, 21280, Turkey; Yavuz M., Department of Chemistry, Faculty of Science, Dicle University, Diyarbakir, 21280, Turkey en_US
dc.description.abstract The concentrations of Cd, Ni, Cu, Pb, Cr, Fe, B, and A1 were determined in four different medicinal plants of the Hyoscyamus species: Hyoscyamus reticulums L, Hyoscyamus leptocalyx STAPF, Hyoscyamus aureus L, and Hyoscyamus albus L by ICP-OES. By considering the sensitivity of ICP-OES with respect to the trace level determination of Cd, Ni, Cu, Pb, Cr, Fe, B, and Al in the studied plant samples and the limitations of sample amount possible in a microwave digestion procedure, the ashing method was applied before analysis and proved the quantitative measurements of the elements.The accuracy of the method was verified by comparison to the certified reference sample NCSZC 73014 Tea Leaves. The RSD values were between 0.14-10.4%, while the error values were in the 90-107% range. The results show that with the proposed method higher concentrations of Ni, Cr, Pb, Fe, and B were determined in H. aureus. Interestingly, the concentration of Cu in H. reticulatus was approximately 48.5 times higher than the mean Cu values of the other three Hyoscyamus species, while the Pb concentration levels in H. aureus were 17.8 times higher than in the H. reticulatus L, H. leptocalyx STAPF, and H. albus L species. en_US
dc.identifier.doi 10.46770/AS.2014.05.002
dc.identifier.endpage 199 en_US
dc.identifier.issn 0195-5373
dc.identifier.issue 5 en_US
dc.identifier.scopus 2-s2.0-84919337029
dc.identifier.scopusquality Q2
dc.identifier.startpage 193 en_US
dc.identifier.volume 35 en_US
dc.identifier.wos WOS:000344511300002
dc.identifier.wosquality Q1
dc.indekslendigikaynak Web of Science en_US
dc.indekslendigikaynak Scopus en_US
dc.language.iso en en_US
dc.publisher Perkin - Elmer Corp. en_US
dc.relation.ispartof Atomic Spectroscopy en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 1
dc.title Trace Metal Determination in the Medicinal Plant Hyoscyamus (Solanaceae) by Inductively Coupled Plasma Optical Emission Spectrometry en_US
dc.type Article en_US
dc.wos.citedbyCount 1
dspace.entity.type Publication
relation.isAuthorOfPublication 372246d5-4a94-4c92-b9e4-3b9bbbbb9d54
relation.isAuthorOfPublication.latestForDiscovery 372246d5-4a94-4c92-b9e4-3b9bbbbb9d54
relation.isOrgUnitOfPublication 256d1c0a-4c75-476b-b468-80c6b6a899f2
relation.isOrgUnitOfPublication.latestForDiscovery 256d1c0a-4c75-476b-b468-80c6b6a899f2

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
keskın.pdf
Size:
154.34 KB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text