Comparative solid phase extraction study on the U(VI) preconcentration by using immobilized thermotolerant Bacillus vallismortis and Bacillus mojavensis
No Thumbnail Available
Date
2018
Journal Title
Journal ISSN
Volume Title
Publisher
SPRINGER
Open Access Color
OpenAIRE Downloads
OpenAIRE Views
Abstract
Bacillus vallismortis and Bacillus mojavensis were loaded onto Amberlite XAD-4 resin and used for solid phase extraction (SPE) of uranium(VI). A quick and simple UV-Vis spectrophotometric method was used to determine U(VI) ion. The best experimental conditions were determined as being a pH of 5.0; a sample flow rate of 2.0 mL min(-1); 200.0 mg of biosorbent; 800 mg of Amberlite XAD-4, and 5.0 mL of 1 mol L-1 HCl as desorption solution for both immobilized bacteria. The preconcentration factors were achieved as 80 for both solid phase extractor. The developed methods were validated by applying to reference water and tea samples.
Description
Keywords
Bacillus vallismortis, Bacillus mojavensis, Amberlite-XAD-4, Solid phase extraction, Preconcentration, U(VI)
Turkish CoHE Thesis Center URL
Fields of Science
Citation
WoS Q
Q3
Scopus Q
Q2
Source
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY
Volume
315
Issue
2
Start Page
185
End Page
193