MAÜ GCRIS Standart veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Confounding Factors in the Tear Break-Up Time Test. Influence of Sequential Measurements

dc.authoridAcet, Yakup/0000-0002-6589-0329
dc.authorscopusid56026525900
dc.authorscopusid55735554500
dc.contributor.authorAcet, Yakup
dc.contributor.authorDag, Yasar
dc.date.accessioned2025-04-16T00:17:01Z
dc.date.available2025-04-16T00:17:01Z
dc.date.issued2025
dc.departmentArtuklu Universityen_US
dc.department-temp[Acet, Yakup] Mardin Artuklu Univ, Fac Med, Dept Ophthalmol, Mardin, Turkiye; [Dag, Yasar] Istanbul Basaksehir Cam & Sakura City Hosp, Dept Ophthalmol, Istanbul, Turkiyeen_US
dc.descriptionAcet, Yakup/0000-0002-6589-0329en_US
dc.description.abstractClinical relevance The tear break-up time (BUT) test is important in diagnosing and monitoring tear film stability, and understanding potential changes in tear film dynamics during repeated measurements could improve the accuracy and reliability of the test in clinical practice. Background The study aimed to examine the changes in BUT value caused by subsequent measurements made in BUT test. Methods A total of 120 female participants were divided into groups (30 individuals each). Participants were divided into four groups based on the interval between two non-invasive tear break-up time (NI-BUT) tests: Group 1 (1-minute interval), Group 5 (5-minute interval), Group 10 (10-minute interval), and Group 15 (15-minute interval). The first NI-BUT test was called Initial NI-BUT (NI-BUT(I)), and the second test was called Subsequent NI-BUT (NI-BUT(S)). The first BUTvalue (BUT1st), the second BUT value (BUT2nd), the third BUT value (BUT3rd), the fourth BUT value (BUT4th), the fifth BUT value (BUT5th), and the average value of the first three BUTs (BUTA3) were compared between the NI-BUT(1) and NI-BUT(S) tests. Results Participant ages ranged from 18 to 36 years, with a mean of 25.1 +/- 3.2 years. The mean values of BUT1st, BUT2(nd), BUT3(rd), BUT4(th), BUT5(th), and BUTA3 in the NI-BUT(I) test were statistically significantly shorter than those in the NI-BUT(S) test for all groups (p < 0.05). The changes in the parameters were statistically significantly greater in Group 1 compared to the other groups (p < 0.05). Conclusions Subsequent measurements cause increased BUT values. The longer the interval between two measurements, the smaller the differences between the subsequent measurements. When performing the BUT test, a single measurement should be preferred if possible. If the clinician finds the results of a single measurement unsatisfactory and wishes to consider the average of multiple measurements, the interval between tests should be longer than 15 minutes.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.1080/08164622.2025.2475202
dc.identifier.issn0816-4622
dc.identifier.issn1444-0938
dc.identifier.pmid40089876
dc.identifier.scopus2-s2.0-105000426489
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1080/08164622.2025.2475202
dc.identifier.urihttps://hdl.handle.net/20.500.12514/8478
dc.identifier.wosWOS:001446065200001
dc.identifier.wosqualityQ3
dc.language.isoenen_US
dc.publisherTaylor & Francis Ltden_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDry Eyeen_US
dc.subjectNon-Invasive Break-Up Time Testen_US
dc.subjectTear Break-Up Timeen_US
dc.subjectTear Filmen_US
dc.titleConfounding Factors in the Tear Break-Up Time Test. Influence of Sequential Measurementsen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isAuthorOfPublicationf42dc63a-56cb-4e35-b675-2421aa3cfa78
relation.isAuthorOfPublication.latestForDiscoveryf42dc63a-56cb-4e35-b675-2421aa3cfa78

Files