Ability of Cha2ds2-vasc/R2cha2ds2-vasc Scores To Predict Complications Related To Cardiac Implantable Electronic Devices

Loading...
Publication Logo

Date

2025

Journal Title

Journal ISSN

Volume Title

Publisher

Wiley

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Average
Popularity
Top 10%

Research Projects

Journal Issue

Abstract

BackgroundGlobally, the number of cardiac implantable electronic devices (CIEDs) is increasing. In our study, we aimed to investigate whether CHA(2)DS(2)-VASc and R(2)CHA(2)DS(2)-VASc scores are predictive of CIED-related complications. MethodsOur investigation was carried out with a multicenter retrospective design. Patients who underwent CIED surgery at two cardiac centers in Turkey between January 2011 and May 2023, 1676, were evaluated. The patients were divided into two groups according to their R(2)CHA(2)DS(2)-VASc scores. Patients with R(2)CHA(2)DS(2)-VASc >= 5 were included in group 1 (380 patients), and patients with R(2)CHA(2)DS(2)-VASc < 5 (1296 patients) were included in group 2. The primary outcome was defined as the cumulative events. Each component of cumulative events, such as hematoma, pericardial effusion, pneumothorax, and infection, was also defined as a secondary outcome. ResultsThe study's patient population had an average age of 62.9 +/- 14 years. Pneumothorax (1.8% vs. 1.3%, p = 0.444), pericardial effusion or tamponade (0.35% vs. 0.2%, p = 0.659), and clinically significant hematoma (1.1% vs. 0.6%, p = 0.376) were comparable between the groups. Infection-related devices and cumulative events classified as primary outcomes were higher in the R(2)CHA(2)DS(2)-VASc >= 5 group (6.1% vs. 1.2%, p < 0.001; 7.6% vs. 3.2%, p < 0.001, respectively). Modeling analyses showed that the CHA(2)DS(2)-VASc score and HT were also independent predictors of device-related infection and cumulative events. ConclusionIn the R(2)CHA(2)DS(2)-VASc >= 5 groups, infection related to the device system and cumulative events were higher. Patients with an R(2)CHA(2)DS(2)-VASc score of 5 or more and a high CHA(2)DS(2)-VASc score should be evaluated more carefully regarding infection and cumulative events before and after the operation.

Description

Soner, Serdar/0000-0002-2807-6424;

Keywords

Cardiac Implantable Electronic Device, CHA(2)DS(2)-VASc Score, Complication, Infection, R(2)CHA(2)DS(2)-VASc Score, Male, Pacemaker, Artificial, Postoperative Complications, Turkey, Humans, Female, Middle Aged, Risk Assessment, Retrospective Studies, Defibrillators, Implantable, Aged, Risk Factors, complication, CHA<sub>2</sub>DS<sub>2</sub>-VASc Score, cardiac implantable electronic device, infection, R<sub>2</sub>CHA<sub>2</sub>DS<sub>2</sub>-VASc score, CHA(2)DS(2)-VASc Score, R(2)CHA(2)DS(2)-VASc score

Fields of Science

Citation

WoS Q

Q3

Scopus Q

Q3
OpenCitations Logo
OpenCitations Citation Count
N/A

Source

Pace-Pacing and Clinical Electrophysiology

Volume

48

Issue

2

Start Page

151

End Page

159
PlumX Metrics
Citations

Scopus : 1

Captures

Mendeley Readers : 2

SCOPUS™ Citations

1

checked on Feb 26, 2026

Web of Science™ Citations

1

checked on Feb 26, 2026

Page Views

3

checked on Feb 26, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
8.85747516

Sustainable Development Goals

SDG data is not available