MAÜ GCRIS Standart veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

The Effect of Aortic Angulation on Clinical Outcomes of Patients Undergoing Transcatheter Aortic Valve Replacement

No Thumbnail Available

Date

2024

Journal Title

Journal ISSN

Volume Title

Publisher

Soc Brasil Cirurgia Cardiovasc

Open Access Color

OpenAIRE Downloads

OpenAIRE Views

Research Projects

Organizational Units

Journal Issue

Events

Abstract

Introduction: The aim of this study was to assess the impact of aortic angulation (AA) on periprocedural and in -hospital complications as well as mortality of patients undergoing Evolut (TM) R valve implantation. Methods: A retrospective study was conducted on 264 patients who underwent transfemoral-approach transcatheter aortic valve replacement with self-expandable valve at our hospital between August 2015 and August 2022. These patients underwent multislice computer tomography scans to evaluate AA. Transcatheter aortic valve replacement endpoints, device success, and clinical events were assessed according to the definitions provided by the Valve Academic Research Consortium -3. Cumulative events included paravalvular leak, permanent pacemaker implantation, new-onset stroke, and in -hospital mortality. Patients were divided into two groups, AA <= 48(degrees) and AA > 48(degrees), based on the mean AA measurement (48.3 +/- 8.8) on multislice computer tomography. Results: Multivariable logistic regression analysis was performed to identify predictors of cumulative events, utilizing variables with a P-value < 0.2 obtained from univariable logistic regression analysis, including AA, age, hypertension, chronic renal failure, and heart failure. AA (odds ratio [OR]: 1.73, 95% confidence interval [CI]: 0.89-3.38, P=0.104), age (OR: 1.04, 95% CI: 0.99-1.10, P=0.099), hypertension (OR: 1.66, 95% CI: 0.82-3.33, P=0.155), chronic renal failure (OR: 1.82, 95% CI: 0.92-3.61, P=0.084), and heart failure (OR: 0.57, 95% CI: 0.27-1.21, P=0.145) were not found to be significantly associated with cumulative events in the multivariable logistic regression analysis. Conclusion: This study demonstrated that increased AA does not have a significant impact on intraprocedural and periprocedural complications of patients with new generation self-expandable valves implanted.

Description

Keywords

Aortic Angulation, Aortic Stenosis, Transcatheter Aortic Valve Replacement, Logistic Models

Turkish CoHE Thesis Center URL

Fields of Science

Citation

WoS Q

Q4

Scopus Q

Q3

Source

Volume

39

Issue

2

Start Page

End Page