Harmonics Mitigation of Stand‑Alone Photovoltaic System Using LC Passive Filter

dc.contributor.author Adak, Süleyman
dc.contributor.other 17.02. Department of Electricity and Energy / Elektrik ve Enerji Bölümü
dc.contributor.other 17. Vocational Higher School / Meslek Yüksekokulu
dc.contributor.other 01. Mardin Artuklu University / Mardin Artuklu Üniversitesi
dc.date.accessioned 2024-01-13T21:14:53Z
dc.date.available 2024-01-13T21:14:53Z
dc.date.issued 2021
dc.description.abstract This article investigates modeling and simulation of the of-grid photovoltaic (PV) system, and elimination of harmonic components using an LC passive flter. Pulse width modulation (PWM) inverter is used to convert the direct current to alternating current. It is very important in terms of energy quality that the inverter output current total harmonic distortion (THDI) is below the value given by standards. Harmonic components have negatively efect on of-grid PV power system. THDI should be kept below a certain level in order to prevent damage to the equipment in the of-grid system and to ensure a higher quality energy fow to reduce the total harmonic distortion (THD) of the solar inverter output current; LC passive flter must be connected to the output of the PWM inverter. There are many types of passive flters for solar inverters. One of the most widely used flter types is the LC flter. LC flters are used in of-grid systems. LC flter is smaller in size and lower cost than other flters. But it is more complicated to determine the parameters of the LC flter. Therefore, in order for the system to remain in a steady state, the parameters must be accurately calculated and analyzed. In this study, the output power of the solar inverter, switching frequency, bus voltage etc. values were determined and LC flter parameters were calculated. Since high inductance values are used in LC flters, the voltage drop increases in these flters. To reduce the voltage drop, the DC bus voltage must be increased, which increases the switching losses. LC flter is connected between the inverter and the nonlinear load to flter the harmonic components produced by the DC/DC boost converter, DC/AC inverter and non-linear load. Matlab/Simulink program was used in Simulation and analysis of of-grid solar system. Solar inverter output current THD was measured as 91.55%. After the LC flter is connected to the system, this value has dropped to 2.62%. en_US
dc.identifier.uri https://doi.org/10.1007/s42835-021-00777-7
dc.identifier.uri https://hdl.handle.net/20.500.12514/5568
dc.language.iso en en_US
dc.publisher Journal of Electrical Engineering & Technology en_US
dc.relation.ispartof Journal of Electrical Engineering & Technology en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Six-pulse rectifer · en_US
dc.subject Total harmonic distortion for current . en_US
dc.subject Passive LC flter · en_US
dc.subject Of-grid photovoltaic system en_US
dc.title Harmonics Mitigation of Stand‑Alone Photovoltaic System Using LC Passive Filter en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id 0000-0003-1436-2830
gdc.author.institutional Adak, Suleyman
gdc.author.institutional Adak, Süleyman
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.description.department MAÜ, Meslek Yüksekokulları, Mardin Meslek Yüksekokulu, Elektrik ve Enerji Bölümü en_US
gdc.description.endpage 2396 en_US
gdc.description.publicationcategory Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.startpage 2389 en_US
gdc.description.volume 16 en_US
gdc.description.wosquality Q3
relation.isAuthorOfPublication 14b65136-262f-4aad-9747-1139728e6581
relation.isAuthorOfPublication.latestForDiscovery 14b65136-262f-4aad-9747-1139728e6581
relation.isOrgUnitOfPublication 18bfdd41-2c86-4bb6-acf5-15548d923960
relation.isOrgUnitOfPublication 7ac23c9e-1f47-4697-a5c8-3fe0c2bfcdb2
relation.isOrgUnitOfPublication 39ccb12e-5b2b-4b51-b989-14849cf90cae
relation.isOrgUnitOfPublication.latestForDiscovery 18bfdd41-2c86-4bb6-acf5-15548d923960

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
mitigation harmonic LC7.pdf
Size:
1.08 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: