Comparison of Evolut-R 34 mm Valve and Smaller Evolut-R Valves in Patients Undergoing Transcatheter Aortic Valve Implantation and Determination of Mild Paravalvular Leak Predictors

Loading...
Publication Logo

Date

2024

Journal Title

Journal ISSN

Volume Title

Publisher

Kare Publ

Open Access Color

GOLD

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Average
Popularity
Average

Research Projects

Journal Issue

Abstract

Objective: The main purpose of this study was to evaluate and compare the in-hospital, 1-month and 1-year post-procedure outcomes of patients treated with Evolut-R 34 mm and Evolut-R 23/26/29 mm devices. Additionally, the study aimed to identify factors that could predict the occurrence of ≥ mild paravalvular leaks (PVL). Methods: Between April 2015 and May 2022, 269 consecutive patients who underwent transcatheter aortic valve implantation (TAVI) with Evolut-R 34 mm (n = 66, 24.5%) and Evolut-R 23/26/29 mm (n = 203, 75.5%) devices in a single center were retrospectively analyzed. Results: Patients in the Evolut-R 34 mm group had a lower female sex ratio (16.7% vs. 66.5%, P < .001, respectively), ejection fraction (50.7 ± 10.1% vs. 54.5 ± 9.3%, P = .016, respectively), and mean aortic gradient (7.4 ± 3.3 vs. 9.2 ± 5.0, P = .026, respectively) compared to the Evolut-R 23/26/29 mm group. The groups did not exhibit any statistically significant dis- tinctions with regard to technical success, the need for a permanent pacemaker, occur- rences of stroke, major vascular complications, PVL, major adverse cardiovascular and cerebrovascular events, or mortality. Peak velocity was confirmed as a significant pre- dictor of ≥mild PVL in both patient groups in the receiver operating characteristic curve analysis. In logistic regression analysis; In patients with Evolut-R 34 mm valve, pre-TAVI aortic valve peak velocity (odds ratio (OR) = 23.202; P = .019) and calcium volume 800 Hounsfield Units (mm3) (OR = 1.017; P < .001) were independent predictors of ≥mild PVL. Conclusion: The Evolut-R 34 mm valve has shown comparable in-hospital results with smaller valve sizes. Pre-TAVI aortic valve peak velocity and calcium volume predicted ≥ mild PVL in Evolut-R 34 mm patients.

Description

Keywords

Transcatheter Aortic Valve Implantation, Paravalvular Leak, Evolut-R 34 Mm, Peak Velocity, Transcatheter aortic valve implantation, Evolut-R 34 mm peak velocity, Paravalvular leak, Original Investigation, Evolut-R 34 Mm, Transcatheter Aortic Valve Implantation, Paravalvular Leak, Peak Velocity

Fields of Science

Citation

Kılıç, R. (2024). Comparison of evolut-r 34 mm valve and smaller evolut-r valves in patients undergoing transcatheter aortic valve implantation and determination of mild paravalvular leak predictors. The Anatolian Journal of Cardiology, 109-117. https://doi.org/10.14744/anatoljcardiol.2023.3563

WoS Q

Q3

Scopus Q

Q3
OpenCitations Logo
OpenCitations Citation Count
N/A

Source

Anatolian Journal of Cardiology

Volume

28

Issue

2

Start Page

109

End Page

117
PlumX Metrics
Citations

Scopus : 1

PubMed : 1

Captures

Mendeley Readers : 6

SCOPUS™ Citations

1

checked on Feb 26, 2026

Web of Science™ Citations

1

checked on Feb 26, 2026

Page Views

4

checked on Feb 26, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.82872147

Sustainable Development Goals

3

GOOD HEALTH AND WELL-BEING
GOOD HEALTH AND WELL-BEING Logo