Selective preconcentration of Lanthanum(III) by Coriolus versicolor immobilised on Amberlite XAD-4 and its determination by ICP-OES

Loading...
Publication Logo

Date

2014

Journal Title

Journal ISSN

Volume Title

Publisher

TAYLOR & FRANCIS LTD

Open Access Color

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Average
Popularity
Average

Research Projects

Journal Issue

Abstract

Coriolus versicolor, a wood fungus, was immobilised on Amberlite XAD-4 and used as solid-phase biosorbent for preconcentrations of rare earth elements. La(III), Th(IV), U(IV) and Ce(III) were subjected to solid-phase extraction procedure. We observed that La(III) was selectively preconcentrated, while other ions remained in solution at pH 6.0. 5.0mL of 1.0molL(-1) HCl was used to elaute La(III) from column. 250mg of C. versicolor loaded on 1000mg of XAD-4 was optimised as solid-phase matrix. Concentrations of ions in solutions were determined by inductively coupled plasma- optical emission spectrometry (ICP-OES). The calibration plot after preconcentration was linear in the range from 1.0 to 50.0ngmL(-1) for La(III). Limit of detection was found as 0.27ngmL(-1) for La(III) by SPE method. Relative standard deviation was found lower than 6.7% for 1.0ngmL(-1) of La(III) solution (n=10). The sensitivity of ICP-OES was improved by a factor of 46.8. The applicability of the method was validated through the analysis of certified reference samples of tea (NCS ZC-73014) and spinach (NCS ZC-73013).

Description

Keywords

Lanthanum, rare earth elements, solid-phase extraction, selective preconcentration, Coriolus versicolor, lanthanum, selective preconcentration, coriolus versicolor, Lanthanum, Coriolus versicolor, rare earth elements, solid-phase extraction, Rare Earth Elements, Selective Preconcentration, Solid-Phase Extraction, Coriolus Versicolor

Fields of Science

01 natural sciences, 0104 chemical sciences

Citation

Özdemir, S., Okumuş, V., Dündar, A., Çelik, K. S., Yüksel, U., & Kılınç, E. (2013). Selective preconcentration of Lanthanum(III) byCoriolus versicolorimmobilised on Amberlite XAD-4 and its determination by ICP-OES. International Journal of Environmental Analytical Chemistry, 94(6), 533–545. https://doi.org/10.1080/03067319.2013.831412

WoS Q

Q3

Scopus Q

Q2
OpenCitations Logo
OpenCitations Citation Count
14

Source

INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY

Volume

94

Issue

6

Start Page

533

End Page

545
PlumX Metrics
Citations

CrossRef : 11

Scopus : 16

Captures

Mendeley Readers : 14

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
1.41184353

Sustainable Development Goals